Universal radio test set RST-430

  • Price/NAR

    $7,692.24



    Pallet Price

    $7,692.24 ($7,692.24/NAR)

    • Package :

    • Items/Pallet:

      1
    • Min. Order:

      1 Pallet(s)


Product Details

Measures

Weight: 4.10 кг
Volume: 0.01 м3
Length: 0.27 м
Width: 0.15 м
Height: 0.25 м

Product Description

A universal radio test set for complete maintenance and repair of FM and AM radio stations of the VHF band

RST-430 Radio-Communication Service Tester is designed for maintenance and repair of FM and AM radio stations operating in the HF and VHF bands. It is a multipurpose radio measuring device for maintenance of communication equipment in indoor and field conditions

A universal radio test set for complete maintenance and repair of FM and AM radio stations of the VHF band



RST-430 Radio-Communication Service Tester is designed for maintenance and repair of FM and AM radio stations operating in the HF and VHF bands. It is a multipurpose radio measuring device for maintenance of communication equipment in indoor and field conditions


Functions

HF generator
LF generator
Frequency meter
Power meter
Dummy load
Modulation meter
Non-linear distortion factor meter
AC voltmeter


Measured parameters

Transmitter carrier power
Transmitter frequency
Ringing frequency
Transmitter frequency deviation
Sensitivity of transmitter modulation input
Non-linear distortion factor of transmitter modulation characteristics
Receiver sensitivity, including the signal-to-noise and distortion ratio (SINAD)
Receiver output voltage
Receiver selectivity
Receiver non-linear distortion factor
Noise suppressor threshold

Standard scope of supply

Radio test set RST-430
AC220/12 V power adapter
Instrument certificate, testing guidance, operation manual
Set of cables
Carrying case

Technical characteristics
1. HF generator
Band 1.6... 470 MHz
Carrier setting error < 10-6*
Deviation in FM mode 0.1 ... 20 kHz(step 10 Hz)
Deviation setting error < 10%
Output signal level (step 1 dBm) -60 (-80)... -126 dBm
Level setting intrinsic error < 3 dB
Auxiliary error < 0.1 µV
Amplitude modulation(option) 0…100%
QAM setting error < 10%
Modulation signal frequency (step 1 Hz) 20 Hz ... 20 kHz

2. LF generator
Frequency band (step1 Hz) 20 Hz ... 20 kHz
Frequency instability < 0.2 Hz
Output signal level (step 10 mV) 0 ... 2 V
Setting error < (0.01+0.03·U)V
Distortion factor < 0.3 %


3. Modulation meter
FM deviation 0.1 ... 20 kHz
Error < (0.1+0.1·D) kHz
Modulation rate 0...100%
Error < 10%


4. Frequency meter
LF 10 Hz ... 100 kHz
HF 1.6... 470 MHz
Reference generator instability < 10-6*


5. Non-linear distortion factor meter
Frequency band 20 Hz ... 10 kHz
Limits 1... 50 %
Error < (5+5·Kmst)%


6. AC voltmeter
Range 0.02 ... 20 V
Frequency band 20 Hz ... 20 kHz
Error < (0.02+0.03·U) V


7. Power meter
Level 0.5 ... 20 W (up to 50 W - w/ external attenuator FAD-2, up to 100 W - w/ FAD-3, by agreement with the Customer) Note that when using the FAD type fix attenuators or analogs for measuring parameters of radio transmitter with the output power above 20 W, the power value measured by the device must be multiplied by the attenuation (fading) ratio of the attenuator by the formula Ratt=10 to the power of Ratt, dB/10)
Error < [10+(Pk/Pmst)] %



* If necessary, a reference generator with stability of up to 5·10-7 can be added.
NVRAM can be used for storage of the test results.
The device can be supplied with a power source which provides not less than 4 hours offline
Also a solar cell battery can be used as a power supply.
Carrying case
Dimensions: 270 × 160 × 270 mm

Request a custom order and get something just for you