Time correction unit ENKS-2

Price from: $ 487

Time correction blocks (BKV) ENKS-2 are intended for organizing SOEB (system for ensuring uniform time). ENKS-2, using signals from navigation satellite systems of precise time (GLONASS, GPS), provides determination of coordinates and exact time and counts the time on the built-in clock. ENKS-2 receives signals from satellite navigation systems using an antenna located outside the building. A special bracket is used to mount the antenna. For time synchronization on servers, workstations and other devices, ENKS-2 provides standard exchange protocols NMEA 0183, SNTP. In telemechanics systems, time synchronization from ENKS-2 is provided using commands of the IEC 60870-5-101 protocol. SMPR ENKS-2 provides accurate time synchronization of the built-in clock of the ENIP-2 measuring digital converters with support for synchronized vector measurements. OLED display, front panel control buttons, and a set of interfaces (RS ‑ 232, RS ‑ 485, Ethernet) that provide a variety of options for using the device. In addition, ENKS-2 provides the formation of a verification signal "1 Hz" (PPS). ENKS-2 is a time measuring instrument, entered in the State Register of Measuring Instruments. … ENKS-2 uses standard exchange protocols NMEA 0183, SNTP for synchronization of servers, workstations and other devices. For time synchronization in telemechanics systems, ENKS-2 supports the command C_CS_NA_1 (103) of the IEC 60870-5-101 exchange protocol. When using ENKS-2 in SMPR together with USVI ENIP-2 (PMU), time synchronization is carried out using the IRIG protocol. In addition, ENKS-2 generates a verification signal "1 Hz" (PPS). ENKS-2 is supplied with initial verification of Tech. specifications Time counting accuracy Allowable absolute error of PPS edge synchronization (1 Hz) and IRIG timing mark to UTC scale – ± 500 ns, minimum time correction quantum – 11 ns, allowable absolute error of time scale reproduction in the absence of communication – ± 0.4 s / day Synchronization frequency according to IEC 60870‑5‑101 C_CS_NA_1 (103) from 1 min to 45 days, IRIG – 100 ms, SNTP – upon client request (up to 10,000 NTP requests per second) Interfaces RS ‑ 232‑1, RS ‑ 485‑1: NMEA 0183, IEC 60870-5-101; RS-232-2: NMEA 0183; RS ‑ 485‑2: IRIG ‑ A, IRIG ‑ B, PPS; Ethernet 100Base-T: SNTP Operating conditions and design -40 to +70 ° С, 83 × 100 × 110 mm (plastic, IP40), DIN-rail mounting

Send Me Quotation

The function is avialable for logged in users only


Category:

Specification

Product value

0,00 м3

Product length

110 мм

Product width

83 мм

Product height

100 мм

Reviews

There are no reviews yet.

Be the first to review “Time correction unit ENKS-2”