Automatic titrator

Price from: $ 1

The titrator is controlled using the Titrate-5.0 software package, which is supplied in three types of configurations with different levels of functionality: basic configuration of the Titrate-5.0 Base; extended configuration of the Titrate-5.0 Deluxe titrator; professional configuration of the Titrate-5.0 Pro titrator; Basic configuration of the Titrate-5.0 Base software package supplied complete with titrator ATP-02. The Titrate-5.0 Deluxe and Titrate-5.0 Pro configurations are supplied for a separate fee. The Titrate-5.0 software package is a modern software product in Russian with great analytical capabilities and a convenient, user-friendly interface built on the principle of intuition. With the help of this program, complete control of the device is carried out during the measurement process, data processing is carried out, the metrological characteristics of the obtained results are calculated, information is stored and the measurement protocols are printed. "and" Researcher ". The" Analyzer "mode implements measurements in strict accordance with the methodology and normative document with full automation of the process of obtaining the result. On the command "Start" automatically occurs: measurement and processing of data; construction of a report; saving the measurement protocol in the database; printing the measurement protocol in accordance with the requirements of the normative document. This mode is most productively used in daily measurements and allows you to minimize errors and errors introduced by the operator … The program guides the operator through the entire procedure, displays the necessary prompts, if necessary, informs about possible errors. In this mode, it is also possible to use target programs that are part of the complex. In the "Explorer" mode, all the huge possibilities of the program open up, such as: creating your own measurement procedures; adjusting existing methods; developing new and changing existing mechanisms for processing measurement results; changes calculation mechanisms and user interfaces; calibration and input of parameters of new electrodes; development of new and correction of existing protocols and printed forms; implementation of all research functions of the complex. Methods and techniques developed in the "Explorer" mode can be further used in the "Analyzer" mode. In addition to the specified configurations of the Titrate-5.0 software package, target programs are supplied to the ATP-02 titrator for performing measurements for special tasks. Some of them: Titrate-5.0 Chlorides. Target program for measuring chloride salts in oil and oil products in accordance with GOST 21534-76 (A), ASTM B 6470-99. Titrate-5.0 Sulfur. Target program for measuring Н2S and mercaptan sulfur in oil and oil products in accordance with GOST 17323-71, ASTM В 3227-00. Titrate-5.0 Uranium. Target program for measuring the concentration of uranium in ores. Titrate Alkalinity-Sh. Target program for determining alkalinity in low-freezing cooling liquids in accordance with GOST 28084-89. Titrate Gas. Target program for measuring mercaptan sulfur and hydrogen sulfide in liquefied hydrocarbon gases in accordance with GOST 22985-90. Titrate-5.0 Gas. Target program for measuring mercaptan sulfur and hydrogen sulfide in combustible natural gases in accordance with GOST 22387.2-97. Titrate Feed. Target program for determining the content of sodium and sodium chloride in compound feeds and feed raw materials in accordance with GOST 13496.1-98. Titrate Chlorides. Target program for measuring chloride salts in oil and oil products in accordance with GOST 21534-76 (B), STSEV 2879-87, USA ASTM D6470-99. Titrate Chloroganika. Target program for measuring organochlorine compounds in oil in accordance with GOST R 52247-2004 (A). Titrate Water_Hydrocarbonates. Target program for the ATP-02 titrator in accordance with PND F 14.2.99-97. Titrate Water_Sulfates. Target program for the ATP-02 titrator in accordance with RD 52.24.453-95.Titrate Water_Chlorides. Target program for the ATP-02 titrator in accordance with GOST 4245-72. Titrate Acid number K1. Target program for determining the acid number in petroleum products in accordance with GOST 11362-96, ISO 6619-88 and standardization of the titrant (KOH) in accordance with GOST 25794.1-83. Titrate Acid number K2. Target program for the ATP-02 titrator for determining the acid number of strong acids in petroleum products in accordance with GOST 11362-96, ISO 6619-88 and standardization of the titrant (KOH) in accordance with GOST 25794.1-83. Titrate Acid number. Target program in accordance with GOST 10858-77 oilseeds. Titrate Acid number. Target program in accordance with GOST 17823.1-72 wood chemical products. Titrate Acid number. Target program in accordance with GOST R 52110-2003 sunflower oils. Titrate Milk-K. Target program for measuring the acidity of milk and dairy products in accordance with GOST 3624-92. Titrate Oil products-K-KCh. Target program for determining the acid number in petroleum products in accordance with GOST 5985-79. Titrate Peroxide number. Target program in accordance with GOST R 51487-99 sunflower oils. Titrate Base number (total) – Щ 2. Target program for determining the base number in petroleum products in accordance with GOST 11362-96, ISO 6619-88. Titrate Chondroitin sulfate. Target program for determining the content of chondroitin sulfate by turbidimetric titration. In laboratories of the pulp and paper industry, the Kappa hardware and software complex is indispensable, consisting of four ATP-02 titrators, an AV-50 moisture analyzer and the Kappa-1.0 program. The complex allows you to determine the Kappa number – an indicator that characterizes the quality of cellulose. Those. specifications Measurement range: by voltage, mV, not less than from – 2000 to 2000 Measurement range by pH value (рХ), units pH (pX units), not less than from – 20 to 20 Measurement range by temperature, ºС, not less from 0 to 100 Maximum titrant volumes in the flask, ml., not less than 20.00 (dose counting is not limited) Readout resolution, ml. , no more than 0.001 The limits of the permissible value are the basis of the absolute error of pH measurement (рХ), for monovalent ions, no more than 0.013.7. Limits of the permissible value by the basis of the absolute measurement error (рХ), for bivalent ions, no more than 0.02 Limits of the permissible value of the basic absolute error of measuring the emf, mV, no more than 1 Limits of the permissible value of the basic absolute error of measuring the temperature, ºС, not more than 1 Limits of the permissible value of the basic relative error of measuring the mass concentration, no more than%  2. The limit of the permissible value of the relative standard deviation of the random component of the error, no more than% 0.5. Power consumption, VA no more than 40.0 current supply voltage, V. 220 ± 22, Hz 50 Weight, kg., not more than 5 Overall dimensions (length, width, height), mm., not more than 210х220х310.3 Operating conditions: • temperature, range, оС, not less than 5 – 40 • relative air humidity,%, not less than 90 Temperature of solutions, range not less than 0 to 100 ºС in Russian. The software included in the delivery set of the titrator implements the following measurement and data processing functions: • Management of measurements by various methods of volumetric titration (direct, reverse, neutralization, oxidation-reduction, complexometry, etc.). • Generation of reports in accordance with the requirements of the normative document; • Saving the measurement protocol in the database; • Printing the measurement protocol; • Creating your own measurement procedures; • Correction of already existing methods; • Development of new and modification of existing mechanisms for processing measurement results; • Calibration and input of electrode parameters; • Development of new and correction of existing protocols and printed forms; • Implementation of titration methods in dynamic and manual modes. • Calibration of the working electrode by concentration • Performing multi-peak processing (processing of several equivalent points with manual or automatic marking of peaks of the 1st derivative of the titration curve) • Filtration of titration curves with four filters (low-frequency, moving average, least squares method and bad areas). Filtration should be performed by each filter separately or by several filters at the same time. • Ability to edit measurement protocols. • Simultaneous loading of several measurement protocols.

Send Me Quotation

The function is avialable for logged in users only


Category:

Specification

Product value

0,01 м3

Product length

21 см

Product width

22 см

Product height

31 см

Product SKU

АТП-02