Multifunctional measuring transducer ENIP-2

Price from: $ 159

The high quality of ENIP-2 measurements is achieved through the use of original signal processing algorithms, which allow performing synchronous measurements of the parameters of the electrical network mode. ENIP-2 has various interfaces and supports standard exchange protocols: Modbus RTU / TCP, IEC 60870-5-101 / 104, as well as the “digital substation” protocol IEC 61850, the implementation quality of which is confirmed by the international certificate DNV GL (KEMA Laboratories). ENIP-2 is produced in three versions: —— in a plastic casing for mounting on a DIN rail (Standard); —— in a metal casing (Compact); —— in a casing with a color liquid crystal touch display (USVI). Executions differ from each other. functional purpose, sets of interfaces and exchange protocols, composition of discrete inputs and outputs. ENIP-2 is easily mounted in the relay compartments of switchgear, on panels or cabinets of the control room. Due to its wide temperature range, the device can be used in unattended unheated facilities. Those. specifications Technical characteristics Measurements In: 1 or 5 A, Un: 57.7 / 100, 220/380 V, 400/690 V (phase / line) RMS value of phase / line and average phase / line voltage Reduced error ± 0.2% relative error ± 0.2% (0.2Unom≤U≤1.5Unom), ± 0.75% (0.05Unom≤U <0.2Unom) RMS value of phase and average current reduced error ± 0.2% relative error ± 0 , 2% (0.2Inom≤I <2Inom), ± 0.75% (0.05Inom≤I <0.2Inom), ± 2.0% (0.01Inom≤I <0.05Inom) Active / reactive / apparent power (phase and total) reduced error ± 0.5% relative error ± 0.5% (0.2 Inom≤I≤2Inom, 0.2Unom≤U≤1.5Unom) Total active / reactive power reduced error ± 0, 5% Frequency absolute error ± 10 MHz Measurement / update time of parameters 50 ms ("sliding window") / 20 ms Additional parameters cosines, tangents, angles (phase and average), active and reactive energy in forward and reverse directions Intervalization of 8 years Discrete inputs 0, 4 or 8 wet contact inputs: Uin 20 … 250 V, filtering of contact bounce Discrete outputs 3 discrete outputs: enable, disable, control; Umax 300 V DC / 250 V ~, Imax 100 mA Measurement of power quality parameters U0, U1, U2, K2U, KU, I0, I1, I2, K2I, KI, THD Expansion modules Indication ENMI ‑ 3, ENMI ‑ 4, ENMI ‑ 5 control and discrete input ENMV ‑ 1‑0 / 3R, ENMV‑ 1‑4 / 3R, ENMV ‑ 1‑6 / 3R, ENMV ‑ 1‑24 / 0, ENMV ‑ 1‑0 / 22, ENMV ‑ 1‑0 / 20, ENMV ‑ 1‑16 / 6, ENMV ‑ 1‑ 16 / 3R (up to 4 modules) Interfaces RS ‑ 485 (600 … 115200 bps) 1 … 3 ports – Modbus RTU, IEC 60870‑5‑101 Ethernet 100Base ‑ T (1 or 2 ports), Ethernet 100Base‑ FX (LC sockets, fiber multimode, 2 ports) IEC 61850, IEC 60870-5-104, IEC 60870-5-101 over UDP, Modbus TCP, Modbus RTU, transparent mode, SNMP 2 port modifications: built-in switch (RSTP, PRP ) Real time clock Time counting accuracy 0.5 ms In the absence of synchronization, the discrepancy is not more than 0.5 s per day Synchronization synchronization from BKV ENKS-2, p o Ethernet (IEC 60870-5-104, SNTP) or via RS-485 ports (IEC 60870-5-101) Logs Binary I / O log, event log Power Supply AC / DC 18 … 36 VDC or 120 … 370 V = / 100 … 265 V ~ (45 … 55 Hz) Power consumption no more than 11 VA (no more than 19 VA with ENMI) Operating conditions and design Operating temperature range / case from –40 to +70 ° С / 75 x 100 x 110 mm (plastic housing, IP40), mounting on 35 mm DIN rail

Send Me Quotation

The function is avialable for logged in users only


Category:

Specification

Product value

0,00 м3

Product length

110 мм

Product width

75 мм

Product height

100 мм